Quido ETH 60/3: 60 inputs, 3 outputs and thermometer

Quido ETH 60/3 includes 60 digital inputs, 3 outputs and thermometer. Quido connects directly to a LAN (Ethernet) and can be fully controlled and managed through a web interface. Inputs are designed t...more information
Power supply contacts, ground, output relay contacts (from left)
Power supply contacts, ground, output relay contacts (from left)
3x output relay contacts, Ethernet interface, external termometer socket (from left)
Quido ETH 60/3: 60x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
3x output relay contacts, Ethernet interface, external termometer socket (from left)
This product includes:
Device from the set above
306,4 EUR excl. VAT 370,7 EUR incl. VAT
More than 5 units in stock
Personally in Prague:Tuesday 2.4.With a delivery company:at the latest Thursday 4.4.
Order CodeQUIDO_ETH_60/3_1Warranty36 monthsCustoms Code84714100Weight234 gCountry of originCZMakerPapouch.com
Power supply contacts, ground, output relay contacts (from left)
Power supply contacts, ground, output relay contacts (from left)
3x output relay contacts, Ethernet interface, external termometer socket (from left)
Quido ETH 60/3: 60x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
3x output relay contacts, Ethernet interface, external termometer socket (from left)

Quido ETH 60/3 includes 60 digital inputs, 3 outputs and thermometer. Quido connects directly to a LAN (Ethernet) and can be fully controlled and managed through a web interface. Inputs are designed to connect voltage or contacts – can distinguish two states (0 and 1). The outputs are relays with a changeover contact. The thermometer can be connected to a cable of up to 15 meters and is able to measure temperatures in the range from -55 to +125 °C.

Thermometers, plexi covers, metal boxeses or DIN rail holder ban be found in Quido accessories.

Features of I/O module

  • Connects directly to LAN (10/100 Ethernet)
  • Controlled by: Web interface, e-mail, Spinel, MODBUS TCP, SNMP, HTTP GET, XML and Wix applications
  • E-mail notification (without SSL/TLS, port 25).
  • For developers: Spinel.NET library on Github with examples in C# (documentation only in Czech)
  • LED indication of power, communication, and the status of inputs and outputs.
  • 60 Galvanically isolated digital inputs for voltage or contacts.
  • 3 Outputs = changeover contact relays.
  • 1 Thermometer with a measuring range of -55 to +125 °C.
  • Automatically sends information about changes on the inputs.
  • Autonomous control based on the measured temperature.
  • Counts pulses on the inputs.
  • Operating temperature of electronics -20 to +60 °C.
  • External power supply 8 to 30 V.
  • Plastic lever for Wago 236 terminals (standard part of delivery).

Basic functions and block diagram of Quido ETH module

Basic functions of I/O modul

  • Reads the current status of inputs
  • Automatically sends information (email, HTTP GET, ...) about changes on the inputs.
  • Counts pulses on the inputs or changes in the status of the input (for first 60 inputs)
  • Control of output relays with a changeover contact
  • Configuration of the outputs for a defined period
  • Thermometer: measuring range of -55 to +125 °C
  • Temperature monitoring (the relay closes when temperature changes, closes for a predefined period when a specified temperature has been reached; sends an e-mail or HTTP GET)

The main page of Quido ETH 8/8

Practical applications

Configuration via web interface (example from Quido ETH 8/8)

WEBVyrobcePapouch.com

quido-eth.pdfDatasheet Quido ETH

Complete documentation for I/O moduls Quido ETH

File size: 2.3 MB

Date: 10.02.2023

Download

quido-modbus-rtu_tcp.pdfQuido Modbus

Complete documentation of Modbus TCP and Modbus RTU in Quido I/O modules

File size: 0,7 MB

Date: 10.02.2023

Download

quido-spinel-en.pdfQuido Spinel EN

Complete documentation of Spinel protocol in Quido I/O modules

File size: 1.4 MB

Date: 18.10.2023

Download

quido-snmp-mib-table.zipSNMP MIB table

SNMP MIB tabule for Quidu.

File size: 2.04 kB

Date: 11.11.2016

Download

Other items:

  • Ethernet Configurator: Universal configuration software for Papouch Ethernet devices. It allows you to set-up your device even from another network range. It can set basic network parameters even for a device in a different subnet than your PC has.
  • Wix: Software for measurement, storing values, controlling and viewing measured-out values from Papouch s.r.o. devices (or others if integrated with for example MODBUS).
  • Spinel: Free universal communication protocol
Power supply contacts, ground, output relay contacts (from left)Power supply contacts, ground, output relay contacts (from left)
3x output relay contacts, Ethernet interface, external termometer socket (from left)3x output relay contacts, Ethernet interface, external termometer socket (from left)
Quido ETH 60/3: 60x digital inputs, 3x output relay, 1x temperature input, Ethernet interfaceQuido ETH 60/3: 60x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
3x output relay contacts, Ethernet interface, external termometer socket (from left)3x output relay contacts, Ethernet interface, external termometer socket (from left)
DescriptionDownloadPicturesAccessories
We value your privacy
This website stores cookies that help it to work properly. By using our services, you agree to their use.
Allow everythingDetailed settings