Quido ETH 100/3 includes 100 digital inputs, 3 outputs and thermometer. Quido connects directly to a LAN (Ethernet) and can be fully controlled and managed through a web interface. Inputs are designed...more information
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
The main page (example of Quido ETH 8/8)
Data in XML format (example of Quido ETH 8/8)
Output control in C# library Spinel.NET
Web interface - network settings
Web interface - security settings
Web interface - e-mail settings
Web interface - SNMP settings
Web interface - HTTP-GET settings
Web interface - input settings
Web interface - pulse output settings
Web interface - temperature watching output settings
Web interface - thermometer settings
Web interface - other settings
Information about the device
This product includes:
Device from the set above
449,8 EUR excl. VAT 544,3 EUR incl. VAT
Custom made
Personally in Prague:nowWith a delivery company:at the latest on request
Order CodeQUIDO_ETH_100/3_5VWarranty36 monthsCustoms Code84714100Weight366 gCountry of originCZMakerPapouch.com
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
The main page (example of Quido ETH 8/8)
Data in XML format (example of Quido ETH 8/8)
Output control in C# library Spinel.NET
Web interface - network settings
Web interface - security settings
Web interface - e-mail settings
Web interface - SNMP settings
Web interface - HTTP-GET settings
Web interface - input settings
Web interface - pulse output settings
Web interface - temperature watching output settings
Web interface - thermometer settings
Web interface - other settings
Information about the device

Quido ETH 100/3 includes 100 digital inputs, 3 outputs and thermometer. Quido connects directly to a LAN (Ethernet) and can be fully controlled and managed through a web interface. Inputs are designed to connect voltage or contacts – can distinguish two states (0 and 1). The outputs are relays with a changeover contact. The thermometer can be connected to a cable of up to 15 meters and is able to measure temperatures in the range from -55 to +125 °C.

Thermometers, plexi covers, metal boxeses or DIN rail holder ban be found in Quido accessories.

Features of I/O module

  • Connects directly to LAN (10/100 Ethernet)
  • Controlled by: Web interface, e-mail, Spinel, MODBUS TCP, SNMP, HTTP GET, XML and Wix applications
  • E-mail notification (without SSL/TLS, port 25).
  • For developers: Spinel.NET library on Github with examples in C# (documentation only in Czech)
  • LED indication of power, communication, and the status of inputs and outputs.
  • 100 Galvanically isolated digital inputs for voltage or contacts.
  • 3 Outputs = changeover contact relays.
  • 1 Thermometer with a measuring range of -55 to +125 °C.
  • Automatically sends information about changes on the inputs.
  • Autonomous control based on the measured temperature.
  • Counts pulses on the inputs.
  • Operating temperature of electronics -20 to +60 °C.
  • External power supply 8 to 30 V.
  • Plastic lever for Wago 236 terminals (standard part of delivery).

Basic functions and block diagram of Quido ETH module

Basic functions of I/O modul

  • Reads the current status of inputs
  • Automatically sends information (email, HTTP GET, ...) about changes on the inputs.
  • Counts pulses on the inputs or changes in the status of the input (for first 60 inputs)
  • Control of output relays with a changeover contact
  • Configuration of the outputs for a defined period
  • Thermometer: measuring range of -55 to +125 °C
  • Temperature monitoring (the relay closes when temperature changes, closes for a predefined period when a specified temperature has been reached; sends an e-mail or HTTP GET)

The main page of Quido ETH 8/8

Practical applications

Configuration via web interface (example from Quido ETH 8/8)

WEBVyrobcePapouch.com

quido-eth.pdfDatasheet Quido ETH

Complete documentation for I/O moduls Quido ETH

File size: 2.3 MB

Date: 10.02.2023

Download

quido-modbus-rtu_tcp.pdfQuido Modbus

Complete documentation of Modbus TCP and Modbus RTU in Quido I/O modules

File size: 0,7 MB

Date: 10.02.2023

Download

quido-spinel-en.pdfQuido Spinel EN

Complete documentation of Spinel protocol in Quido I/O modules

File size: 1.4 MB

Date: 18.10.2023

Download

quido-snmp-mib-table.zipSNMP MIB table

SNMP MIB tabule for Quidu.

File size: 2.04 kB

Date: 11.11.2016

Download

Other items:

  • Ethernet Configurator: Universal configuration software for Papouch Ethernet devices. It allows you to set-up your device even from another network range. It can set basic network parameters even for a device in a different subnet than your PC has.
  • Wix: Software for measurement, storing values, controlling and viewing measured-out values from Papouch s.r.o. devices (or others if integrated with for example MODBUS).
  • Spinel: Free universal communication protocol
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interfaceQuido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
Quido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interfaceQuido ETH 100/3: 100x digital inputs, 3x output relay, 1x temperature input, Ethernet interface
The main page (example of Quido ETH 8/8)The main page (example of Quido ETH 8/8)
Data in XML format (example of Quido ETH 8/8)Data in XML format (example of Quido ETH 8/8)
Output control in C# library Spinel.NETOutput control in C# library Spinel.NET
Web interface - network settingsWeb interface - network settings
Web interface - security settingsWeb interface - security settings
Web interface - e-mail settingsWeb interface - e-mail settings
Web interface - SNMP settingsWeb interface - SNMP settings
Web interface - HTTP-GET settingsWeb interface - HTTP-GET settings
Web interface - input settingsWeb interface - input settings
Web interface - pulse output settingsWeb interface - pulse output settings
Web interface - temperature watching output settingsWeb interface - temperature watching output settings
Web interface - thermometer settingsWeb interface - thermometer settings
Web interface - other settingsWeb interface - other settings
Information about the deviceInformation about the device
DescriptionDownloadPicturesAccessories
We value your privacy
This website stores cookies that help it to work properly. By using our services, you agree to their use.
Allow everythingDetailed settings